C. replace in-line fuel strainer, 500 hour intervals), Unlock and open the right rear engine access door – SkyTrak 6042 Operation Manual User Manual

Page 131: Close and lock the right rear engine access door, General maintenance

Advertising
background image

General Maintenance

129

Model 6042

Origin 2/04

C. Replace In-line Fuel Strainer

(500 Hour Intervals)

1. Unlock and open the right rear

engine access door.

2. The in-line fuel strainer (3) is located down line from the engines lift

pump (4). Loosen the two hose clamps (5) that secure the strainer
in place.

3. Remove the old in-line fuel strainer and dispose of properly.

4. Install the new in-line fuel strainer (3) with arrow pointing toward the

lift pump (4).

5. Assemble the hoses to the in-line fuel strainer and tighten the hose

clamps.

6. Remove air from the fuel system (see “Bleeding Fuel System” on

page 130).

7. Close and lock the right rear engine access door.

500

OT1150

OA1700

3

5

4

Advertising