9-35

6036, 6042, 8042, 10042, 10054

Electrical System

489

191

18

Amber

Transmission

Output Shaft

Speed

Transmission Output Shaft Speed—Data Valid but Below
Normal Operational Range—Moderately Severe Level

3328

191

9

Amber

Transmission Output Shaft Speed—Abnormal update rate

2375

412

3

Amber

Exhaust Gas
Recirculation

(EGR)

Temperature

Exhaust Gas Recirculation (EGR) Temperature Sensor
Circuit— Voltage Above Normal, or Shorted to High Source

2376

412

4

Amber

Exhaust Gas
Recirculation

(EGR)

Temperature

Exhaust Gas Recirculation (EGR) Temperature Sensor
Circuit— Voltage Below Normal, or Shorted to Low Source

2961

412

15

None

Engine Intake

Valve Actuator

#12

Exhaust Gas Recirculation (EGR) Temperature—Data Valid
But Above Normal Operating Range—Least Severe Level

292

441

14

Red

Auxiliary

Temperature 1

Auxiliary Temperature Sensor Input 1—Special Instructions

293

441

3

Amber

OEM

Temperature

Auxiliary Temperature Sensor Input # 1 Circuit—Voltage
Above Normal, or Shorted to High Source

294

441

4

Amber

OEM

Temperature

Auxiliary Temperature Sensor Input # 1 Circuit—Voltage
Below Normal, or Shorted to Low Source

431

558

2

Amber

Accelerator

Pedal Low Idle

Switch

Accelerator Pedal or
Lever Idle Validation Circuit - Data Erratic, Intermittent, or
Incorrect

432

558

13

Red

Accelerator

Pedal Low Idle

Switch

Accelerator Pedal or Lever Idle Validation Circuit - Out of
Calibration

523

611

2

Amber

System

Diagnostic

code # 1

OEM Intermediate (PTO) Speed switch Validation—Data
Erratic, Intermittent, or Incorrect

2186

611

4

Amber

System

Diagnostic

code # 1

Sensor Supply 4 Circuit—Voltage Below Normal, or Shorted to
Low Source

115

612

2

Red

System

Diagnostic

Code # 2

Engine Speed/Position Sensor Circuit lost both of two signals
from the magnetic pickup sensor—Data Erratic, Intermittent,
or incorrect

244

623

4

Amber

Red Stop

Lamp

Red Stop Lamp Driver Circuit—Voltage Below Normal, or
Shorted to Low Source

351

627

12

Amber

Controller #1

Injector Power Supply - Bad Intelligent Device or Component

Fault

Code

SPN

Code

FMI

Code

LAMP

Area

Description

Diagnostic Description