Installation of first roof panel – Mueller Pre-Fab User Manual

Page 58

Advertising
background image

877-2-MUELLER

E-12

InsTallaTIon of fIRsT Roof Panel

Once the eave is prepared, the first roof panel may be installed . Check the erection drawings to
determine the roof overhang at the eave . Set the roof panel in place over the inside closure (after
removing the paper from the sealant tape) ensuring the major ribs of the panel nest properly
with the inside closure . Align the center of the major rib of the panel edge with the edge of the
endwall roofline . With the panel properly placed, secure the panel to the structure with appropriate
fasteners . If the building requires more than one panel per run, do not install fasteners at the purlin
located at the upslope end of the panel . These fasteners will be installed after the overlapped
panel is installed .

Wall Panel

Eave Flashing

Blanket

Insulation

Eave

Strut

Double-sided Tape

Inside

Closure

Panel

Panel Rib

Endwall

Roof Line

Purlin

As required

on erection

drawings

noTe: for a professional finish, roof panel ribs should be in line with

wall panel ribs.

WaRnInG! Do not walk on unsecured panels. Wipe oil and other slippery

substances from roof panels. safeTY fIRsT!

Advertising