Table 11 – Brocade Communications Systems Brocade Backbone DCX 8510-4 User Manual

Page 116

Advertising
background image

96

Brocade DCX 8510-4 Backbone Hardware Reference Manual

53-1002177-05

Brocade DCX 8510-4 chassis removal and replacement

5

Intermittent FAULTY codes for blades. Re-seat the blade and visually inspect the right-hand
ejector stiffening rail for possible wear or damage. It is important that the blade ejector
handles not slip out during blade installation. If this happens, it is usually due to excessive
wear or damage to the right-hand ejector stiffening rail.

The psShow or fanShow commands continue to show a faulty component even though the
component was replaced.

The slotShow command continues to show a faulty control processor, core switch, or port blade
even though the blade was replaced.

Recording critical Brocade DCX 8510-4 and SAN information

All commands must be entered from a CLI session (Telnet or serial) to the active CP blade unless
otherwise indicated.

NOTE

Run supportShow, which includes most of the information in Table 1 and more. The customer should
record the location of the .txt files, which are created by the customer in this procedure and are not
called out in the supportShow results.

For detailed information about Fabric OS commands, refer to the Fabric OS Command Reference
Manual
. Use a checklist (Table 1) to ensure that all required information is recorded.

TABLE 11

Critical information checklist

Checked?

Data

Notes

Configuration information

Location of “config-switch.txt” file

Location of “config-miscinfo.txt” file

IP address, subnet mask

WWN for Brocade DCX 8510-4

SAN profile

Location of “SANbefor.txt” file

Notes regarding nsshow output

Notes regarding nsallshow output

Notes regarding switchshow output

Notes regarding fabricshow output

Output from supportshow command

Location of “spptshow.txt” file

Notes regarding supportshow output

Information about the new chassis

New factory serial number

New serial number (if available)

Advertising