Brocade Communications Systems Brocade Backbone DCX 8510-4 User Manual

Page 117

Advertising
background image

Brocade DCX 8510-4 Backbone Hardware Reference Manual

97

53-1002177-05

Brocade DCX 8510-4 chassis removal and replacement

5

1. Open a Telnet session and log in to the Brocade DCX 8510-4 as admin. The default password is

password. Enable the logging function on your Telnet or serial console connection.

2. Back up the current configuration.

NOTE

If you are using the Virtual Fabric feature, you should run configupload -vf before running the
configupload command to save the logical switch configuration.

Enter configUpload -all; then enter the requested information at the prompts.

This command uploads the Brocade DCX 8510-4 configuration to the customer-defined
FTP server, making it available for downloading. For more information about this
command, refer to the Fabric OS Command Reference.

switch:admin> configupload

Protocol (scp or ftp) [ftp]: ftp

Server Name or IP Address [host]: 123.123.123.123

User Name [user]: Admin24

File Name [config.txt]: config-switch0.txt

Password:

Upload complete

switch:admin>

Alternatively, you can save the configuration file to a Brocade USB device.

3. Record the WWN value: Enter wwn; then copy the command output into a file named

config-miscinfo.txt.

switch:admin> wwn

10:00:00:60:69:00:00:0a

4. Record the IP address information.

Enter ipAddrShow -sw; then copy the command output into the config-miscinfo.txt file.

switch:admin> ipaddrshow -sw

SWITCH

Ethernet IP Address: 10.32.50.12

Ethernet Subnetmask: 255.55.0.0

Fibre Channel IP Address: 1.2.3.4

Fibre Channel Subnetmask: 255.255.255.0

CP0

Ethernet IP Address: 10.32.50.10

Ethernet Subnetmask: 255.55.0.0

HostName : cp0

Gateway Address: 10.32.40.1

CP1

Ethernet IP Address: 10.32.50.11

Ethernet Subnetmask: 255.55.0.0

HostName : cp1

Gateway Address: 10.32.40.1

Backplane IP address of CP0 : 10.0.0.6

Backplane IP address of CP1 : 10.0.0.7

switch:admin>switch:admin>