14

Brocade DCX 8510-4 Backbone Hardware Reference Manual

53-1002177-05

Preparing for Brocade DCX 8510-4 installation

2

Preparing for Brocade DCX 8510-4 installation

NOTE

Read the safety notices before installation (

“Safety notices”

).

Read

“Power specifications”

to plan for meeting power supply standards before installing the

chassis.
Read

“Managing cables”

to plan for cable management.

TABLE 2

Installation tasks, time, and items required

Installation task

Time estimate

Items required

Site preparation and unpacking Brocade
DCX 8510-4

30 minutes

1/2-in. socket wrench (to remove pallet bolts).
#2 Phillips screwdriver
(for cable management comb).
Pallet jack.
Hydraulic lift or assisted lift, able to raise to a
minimum of 140 cm (55 in.), with a minimum
capacity of 113 kg (250 lb). The Brocade DCX
8510-4 weighs 68 kg (150 lb) with four
FC16-48 port cards installed (192 ports).

Installing rack mount kit or
port side exhaust kit

30 minutes

Refer to the one or more of the following if you
are mounting the Brocade DCX 8510-4 in a
rack:
Brocade Port Side Exhaust Kit Installation
Procedure
Brocade DCX 8510-4, DCX-4S Mid-Mount Rack
Kit Installation Procedure
or
Brocade DCX 8510-4, DCX-4S Rack Kit
Installation Procedure.

Mounting and securing Brocade DCX
8510-4 in rack

30 minutes

Installing power cables and powering on
the Brocade DCX 8510-4

20 minutes

Power cables (provided in the Brocade DCX
8510-4 accessory kit).

Establishing serial connection, logging on
to Brocade DCX 8510-4, and configuring IP
addresses

20 minutes

Serial cable (provided in the accessory kit).
Workstation computer with a serial port or
terminal server port and a terminal emulator
application (such as HyperTerminal).
Ethernet IP addresses for the Brocade DCX
8510-4 chassis and for both control processor
blades: total three addresses.

Installing an Ethernet cable, opening a
Telnet session, and configuring the
Brocade DCX 8510-4 domain ID, date and
time, and additional system parameters.
Verify and back up configuration.

20 minutes

Ethernet cabling (optional) for Telnet access.
Refer to the Fabric OS Administrator’s Guide.

Installing transceivers as needed

20 minutes (longer
if using high-density
port blades)

SFP+, mSFP, and QSFP optical transceivers as
needed.

Attaching fiber-optic cables, cable ties, and
cable guides

2-3 hours

Fiber-optic cables, cable ties, and cable comb.

Advertising