Obtaining chassis and component status, Interpreting post and boot results, Post – Brocade Communications Systems Brocade Backbone DCX 8510-4 User Manual

Page 154: Table 25, Interpreting post and, Boot results

Advertising
background image

134

Brocade DCX 8510-4 Backbone Hardware Reference Manual

53-1002177-05

Obtaining chassis and component status

C

Obtaining chassis and component status

The CLI commands in

Table 25

provide status and environmental information about the chassis

and its components. These commands provide information only, and they do not interrupt traffic
flow. For more information about these commands, refer to the Fabric OS Command Reference.

Interpreting POST and boot results

The Brocade DCX 8510-4 performs Power On Self Test (POST) by default each time the chassis is
powered on, rebooted, or reset. The Brocade DCX 8510-4 can be rebooted using the reboot (to
reboot each CP individually) or fastBoot commands. The fastBoot command reboots the switches
without running POST. If the active CP blade is rebooted, it fails over to the standby CP blade.

POST

The Brocade DCX 8510-4 automatically performs POST each time it is powered on or reset.

To verify that POST has completed without error:

Verify that all LEDs return to a normal state after POST completes.
If one or more LEDs do not return to a normal state, and this is not due to the Brocade DCX
8510-4 being set to beacon, refer to the relevant LED table to identify and correct the problem.
For port blades, and CP and core switch blades, the slotShow command can be used to check
the status of the slots. For information about turning beaconing on/off, refer to the Fabric OS
Administrator’s Guide
.

Verify that the switch prompt displays when POST completes.
If it does not display, POST was not successfully completed. Contact the Brocade DCX 8510-4
supplier for support.

TABLE 25

Environmental status and maintenance commands

Command

Information displayed

sensorShow

Temperature readings for the port blades

Temperature readings for the CP blades

Status and RPM of all operational fans

Status of all operational power supplies

tempShow

Temperature readings for the port blades

Temperature readings for the CP blades

psShow

Status of all operational power supplies

fanShow

Status and RPM of all operational fans

chassisShow

Serial number, time awake, and additional information about each component

slotShow

Slot occupancy

errShow
errDump

System error log. Refer to the Fabric OS Message Reference for more information on the
messages in this log.