Brocade Communications Systems Brocade Backbone DCX 8510-4 User Manual

Page 118

Advertising
background image

98

Brocade DCX 8510-4 Backbone Hardware Reference Manual

53-1002177-05

Brocade DCX 8510-4 chassis removal and replacement

5

5. Display and record the manufacturer serial numbers.

Enter chassisShow; then copy the command output into the config-miscinfo.txt file.

“Factory Serial Num” and “Serial Num” are listed under “Chassis/WWN Unit 1.” If the current
WWN cards are the original cards, the factory serial number listed is the same as the chassis
serial number.

switch:admin> chassisshow

Chassis Backplane Revision: 1F

SW BLADE Slot: 1

Header Version: 2

Power Consume Factor: -50

Factory Part Num: 60-0001532-03

Factory Serial Num: KP000000195

Manufacture: Day: 1 Month: 1 Year: 2007

Update: Day: 14 Month: 3 Year: 2012

Time Alive: 187 days

Time Awake: 3 days

<output truncated>

CHASSIS/WWN Unit: 1 (in same assembly as WWN Unit: 2)

Header Version: 2

Power Consume Factor: -3

Factory Part Num: 60-0001501-07

Factory Serial Num: FT02X805BE2

Manufacture: Day: 26 Month: 3 Year: 2007

Update: Day: 14 Month: 3 Year: 2009

Time Alive: 207 days

Time Awake: 3 days

<output truncated>

switch:admin>

6. Create a SAN “profile” by entering and recording the information provided by the following

commands:

nsShow

nsAllShow

switchShow -qsfp

fabricShow

Copy the command output into a text file named “SANbefor.txt.” After the Brocade DCX 8510-4
is restored to the fabric, this information can be used to verify that no unintentional changes
have occurred to the fabric.

switch:admin> nsshow

Enter Pid COS PortName NodeName TTL

<output truncated>

switch:admin> nsallshow

12 Nx_Ports in the Fabric

<output truncated>

switch:admin> switchshow