FORM-ENG-0018 REV A 05-27-03

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

TECHNICAL DATA SHEET

PAGE

19

OF 36

DATE

6/19/2014

PRODUCT GROUP

THROTTLE CONTROL

P/N

3045-101-00-CL1, 3045-102-00-CL1

REV

1.02

PRODUCT

SENTRY PRESSURE GOVERNOR

BY

AMS


For example: The SENTRY is maintaining the operator’s desired engine speed of 1100 RPM (at a discharge
pressure of 100 PSI). The discharge pressure increases to 160 PSI (e.g. a discharge line was closed) and the
SENTRY decreases the engine RPM until the discharge pressure is reduced to 150 PSI (50 PSI differential).

5.3.5.

Communication with engine is lost

The SENTRY receives engine RPM data via CAN communication (PGN 61444, SPN 190). The SENTRY displays
this warning message after not receiving the RPM data for 4 or more seconds.

Note: If the SENTRY is configured for a CAN control and this warning message is active due to a CAN bus
problem, then the control of the engine RPM cannot be certain since the engine ECU may not receive engine
speed request data from the SENTRY.