FORM-ENG-0018 REV A 05-27-03

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

TECHNICAL DATA SHEET

PAGE

22

OF 36

DATE

6/19/2014

PRODUCT GROUP

THROTTLE CONTROL

P/N

3045-101-00-CL1, 3045-102-00-CL1

REV

1.02

PRODUCT

SENTRY PRESSURE GOVERNOR

BY

AMS


Defaults:

Unit of measure

= PSI, °F

First mode

= Pressure

Idle speed

= 700 RPM

Preset RPM 1

= 1000

Intake sensor range

= 300 PSI

Maximum speed

= 2400 RPM

Preset pressure 1

= 100

Discharge sensor range

= 300 PSI

Source ID

= 7

Preset RPM 2

= 1000

Inhibit RPM presets

= NO

Pressure time out

= 8 seconds

Preset pressure 2

= 100

Warning source

= CAN Bus

RPM mode gain

= 750 RPM/v

Brightness day

= 70

Coolant temp warning

= 180 °F

Pressure mode gain

= 1 PSI

Brightness night

= 50

Coolant temp critical

=230 °F

Dither enable

= NO

Round pressure

= YES

Oil pressure warning

= 40 PSI

Pressure lag

= 5 PSI

Day/night mode

= DAY

Oil pressure critical

= 20 PSI

BCM1 version

= 1

Alert tone

= ENABLE

System voltage

= 12 volts

Scania mode

= NORMAL

Pressure sensitivity

= 5 PSI

Engine control method

= CFPG

Twister rotation increase = CW

Intake pressure offset

= 0

Control auto mode

= Disabled

Display Fuel Economy

= YES

Discharge pressure offset = 0

Idle voltage

= 0.5 volts

Display Trans. Temp

= YES

Display Oil Pressure

= YES

USER menu

OEM1 menu

OEM2 menu

FACTORY menu

6.3.5.

Autoscale Analog Output

A SENTRY set to Analog control mode (see section 6.6.2) may use the Auto Scale configure method to

automatically set the IDLE voltage (see sections 6.3.5 and 6.6.4) and GAIN setting (6.6.9).
The engine must be running and the interlocks (as defined in section 4.3) must be enabled when running the Auto
Scale mode.
Enter the INFO menu and select “AutoScale Analog Output” then press the SAVE button. The display will prompt
you to verify that you want to set the Auto Scale the analog output. Press the green accept button to reset or the
red cancel button to not reset. If the engine control method is not set for “analog” a warning will be shown and Auto
Scale will not be attempted. Once back to the INFO menu you must press the SAVE button to save the Auto Scale
operation and exit the menu.

6.4. USER menu

The User Menu allows configuration of standard user modifiable items.

Unit of measure

Preset RPM 1

Preset pressure 1

Preset RPM 2

Preset pressure 2

Brightness, day

Brightness, night

Round pressure

Display mode


Use the soft buttons to navigate and modify options.