Technical details, Technical data sheet – Class1 3041-10X-00-CL1 - Sentry Governor - EXTERNAL User Manual

Page 36

Advertising
background image

FORM-ENG-0018 REV A 05-27-03

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

TECHNICAL DATA SHEET

PAGE

35

OF 36

DATE

6/19/2014

PRODUCT GROUP

THROTTLE CONTROL

P/N

3045-101-00-CL1, 3045-102-00-CL1

REV

1.02

PRODUCT

SENTRY PRESSURE GOVERNOR

BY

AMS


10. Technical Details

Product category

ES-Key network (SAE J1939 CAN)

Voltage range

+9VDC…+32VDC

Maximum current draw

@13.8VDC

@27.6VDC

Logic supply+ input (pin 1 of connector B)
240 mA
120 mA

Maximum output current

Sensor (+5VDC) References

Alarm active


250mA
250mA (ground polarity output)

Temperature range

-40ºC…+85ºC

Environmental range

IP 67

CAN specification

SAE J1939, 250 Kbits/second

Electrical protection

Internal thermal fuse (2500mA on pin 1 of black 12-pin connector)
CAN bus protected for heavy duty trucks (24V)
Transient voltage protected to SAE J1113 specification for heavy duty trucks (24V)
Load dump voltage protected to SAE J1113 specification for heavy duty trucks (24V)

Electrical performance

Immunity to Radiated Electromagnetic Fields– Bulk Current

Injection (BCI) method, Class C device

SAE J1113-4

Reverse voltage protection on power leads (pins 1 and 12 of black

12-pin connector), Class C device

ISO 16750-2

Jump start on power leads, Class C device

ISO 16750-2

Immunity to conducted transients on power leads, Class C device

(24V)

SAE J1113-11

Immunity to Electrostatic Discharge – powered and unpowered

modes

SAE J1113-13

Immunity to radiated electromagnetic fields

SAE J1113-21

Conducted emission on power leads (level 3 limits)

SAE J1113-41

Radiated emissions, absorber-lined shielded enclosure (level 2

limits)

SAE J1113-41

Reset behavior on voltage drop 24V, Class C device

ISO 16750-2

Environmental performance

Exposure to fungus

MIL-STD-810F
(method 508.5)
SAE J1455
(sec 4.6)

Thermal shock

SAE J1455
(sec 4.1.3.2)

Exposure to humidity

MIL-STD-810F
(method 507.4)

Thermal shock due to splash

Class 1
(STD-0001)

Steam cleaning

SAE J1455
(sec 4.4)

Exposure to salt spray atmosphere/fog

SAE J1455
(sec 4.3)

Exposure to splash due to chemicals and oils

SAE J1455
(sec 4.4)

Exposure to outdoor UV

ISO 4892-2
(method A)

Mechanical performance

Resonance dwell

SAE J1455
(sec 4.9.4.1)

Random vibration

SAE J1455
(sec 4.9.4.2)

Mechanical shock

SAE J1455
(sec 4.10.3.4)

Advertising