Oem 2 menu, Battery voltage range, Engine control method – Class1 3041-10X-00-CL1 - Sentry Governor - EXTERNAL User Manual

Page 27: Auto mode, On 6.6.2 ), Technical data sheet

Advertising
background image

FORM-ENG-0018 REV A 05-27-03

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

TECHNICAL DATA SHEET

PAGE

26

OF 36

DATE

6/19/2014

PRODUCT GROUP

THROTTLE CONTROL

P/N

3045-101-00-CL1, 3045-102-00-CL1

REV

1.02

PRODUCT

SENTRY PRESSURE GOVERNOR

BY

AMS


6.6. OEM 2 menu

The OEM 2 Menu allows configuration of OEM modifiable items. The OEM 2 menu
requires a password (9769).

Battery voltage range

Engine control method

Auto Mode

Idle voltage

Idle Speed

Maximum Speed

Source ID

Pressure time-out

Governor gain

Pressure gain

Dither

Pressure lag

BCM1 version

Scania mode


Use the soft buttons to navigate and modify options.

6.6.1.

Battery Voltage Range

Enter the OEM 2 menu and select “Batt. Voltage (volts)” then press the INCREASE or DECREASE buttons to
change to the desired value (+12 or +24). Press the SAVE button to save the OEM 2 menu items and exit the
menu.

6.6.2.

Engine Control Method

This menu item allows configuration of the engine control type.
CFPG – Cummins Fire Pressure Governor, uses Cummins proprietary control message via CAN to control engine

speed.

PGN0 – Uses J1939, PGN0 – Torque Speed Control message to control engine speed.
SCAN – SCANia, uses the Scania Bodywork Control Message 1.

ANLG – Uses analog voltage signal to control remote throttle input on engine.
MERC – Specific J1939 messaging structure for certain Mercedes applications.
SLAV – Is the second Sentry on the vehicle (slave).

Enter the OEM 2 menu and select “Control Method” then press the INCREASE or DECREASE buttons to change
to the desired value (CFPG, PGN0, SCAN, ANLG, MERC, SLAV). Press the SAVE button to save the OEM 2
menu items and exit the menu.

6.6.3.

Auto Mode

This menu item allows configuration of automatically entering pressure mode when pump engagement occurs
(Auto Mode = ENABLED). Note that this option will only be available if the 1

st

mode parameter (section 6.5.3) is set

to pressure mode. When this parameter is enabled, the governor will be put in pressure mode when the pump is
changed from a disengaged to an engaged position (interlocks permitting). Thereafter, when a user selects the
IDLE (standby) mode, the governor will remain in standby mode until a new mode is selected or the Twister knob is
turned in the “increase” direction (interlocks permitting).

Advertising