1.4 FUNCTION SPEEDS

Machine Orientation When Doing Speed
Tests

Lift: Telescope Retracted. Lift Up, Record Time, Lift Down,
Record Time.

Swing: Boom at Full Elevation. Telescope Retracted.
Swing the Turntable off center and stop. Swing the oppo-
site direction and start the test when the turntable is cen-
tered up. This eliminates ramp up and down on the
controller affecting times.

Telescope: Boom at Full Elevation; Telescope Retracted;
Telescope Out, Record Time. Telescope In, Record Time.

Drive (Forward/Reverse): Test should be done on a
smooth level surface. Drive Select Switch should be set to
High Engine. Start approximately 25 ft. (7.62 m) from the
starting point so that the unit is at maximum speed when
starting the test. Results should be recorded for a 200 ft.
(60.96 m) course. Drive Forward, Record Time. Drive
Reverse, Record Time.

Drive (Above Horizontal): Test should be done on a
smooth level surface. Drive Select Switch should be set to
Low Engine. The boom should be raised above horizon-
tal. Results should be recorded for a 50 ft. (15.24 m)
course. Drive Forward, Record Time. Drive Reverse,
Record Time.

Platform Rotate: Platform level and completely rotated
one direction. Rotate the opposite direction, Record Time.
Rotate the other direction, Record Time.

Articulating Jib: Platform level and centered with the
boom. Start with the Jib down. Jib Up, Record Time. Jib
Down, Record Time.

Test Notes

1. Stop watch should be started with the function, not

with the controller or switch.

2. All speed tests are run from the platform. These

speeds do not reflect the ground control operation.

3. The platform speed knob control must be at full

speed (turned clockwise completely).

4. Function speeds may vary due to cold, thick hydrau-

lic oil. Test should be run with the oil temperature
above 100° F (38° C).

5. Some flow control functions may not work with the

speed knob clicked into the creep position.

Table 1-15. Function Speeds (In Seconds)

Function

600S

Lift Up

46-60

Lift Down

33-43

Swing Right & Left*

79-101

Telescope Out

50-67

Telescope In

25-33

Platform Rotate Right & Left**

16-25

Jib Up

22-34

Jib Down

16-26

Drive Forward & Reverse (2WD)
Forward
Reverse

30-34
38-42

Drive Forward & Reverse (4WD)

30-34

Drive Above Horizontal (2WD)
Forward
Reverse

46-54
58-68

Drive Above Horizontal - Forward & Reverse
(4WD)

46-54

*Max 10% Difference Between Left & Right
**Max 15% Difference Between Left & Right