SECTION 5 - HYDRAULICS

5-18

– JLG Lift –

3121202

5.5 VARIABLE DISPLACEMENT PUMP (M46

SERIES)

Troubleshooting

GAUGE INSTALLATION

It will be necessary to install a high pressure gauge into
the system pressure gauge ports to check the setting of
the high pressure relief valves.

Measuring the charge pump inlet vacuum will help locate
restrictions in the inlet lines, filter, etc.

Case pressure readings can help locate restrictions in the
return lines, oil cooler, and return filter.

Gauge Information

M1

System Pressure
Port A

10, 000 PSI or 600 Bar Gauge

9/16-18 O-ring Fitting

M2

System Pressure
Port B

10, 000 PSI or 600 Bar Gauge

9/16-18 O-ring Fitting

M3

Charge Pressure

1000 PSI or 60 Bar Gauge

9/16-18 O-ring Fitting or Tee into

Charge Pressure Filter Outlet Line

L1
L2

Case Pressure

1000 PSI or 60 Bar Gauge

1-1/16-12 O-ring Fitting

S

Charge Pump Inlet
Vacuum

Vacuum Gauge

Tee into Charge Pump Inlet Line

M4

Servo Pressure

1000 PSI or 60 Bar Gauge

9/16-18 O-ring Fitting

M5

Servo Pressure

1000 PSI or 60 Bar Gauge

9/16-18 O-ring Fitting