Loop flushing valve, Loop flushing valve -20, Loop flushing spool -20 – JLG 660SJ Service Manual User Manual

Page 70

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3-20

– JLG Lift –

3121202

Loop Flushing Valve

REMOVAL

1. Using a 11/16 in internal hex wrench remove plug

(1) and (2).

2. Using a 1/4 in hex wrench remove plug (3).

3. Remove O-rings (4, 5, and 6).

4. Using pliers, remove centering springs (7, 8, and 9).

5. Remove spring retaining washers (10 and 11).

6. Remove shift spool (12).

7. Remove orifice poppet (13).

INSPECT THE COMPONENTS

Inspect new O-rings and the sealing area for rust, wear, or
contamination. Also check springs and poppet for wear.

INSTALLATION

1. Install orifice poppet (13).

2. Install shift spool (12).

3. Install spring retaining washers onto springs (10 and

11).

4. Carefully install centering springs (7, 8, and 9).

5. Install new O-rings (6, 4, and 5).

6. Using a 1/4 in hex wrench torque plug (3) to 20 ft.

lbs. (27 Nm).

7. Using a 11/16 in internal hex, torque plugs (2 and 1)

to 27 ft.lbs. (37 Nm).

2

6

9

11

1

4

8

10

12

5

3

7

13

(37 Nm)

27 ft.lbs.

11/16 in

(37 Nm)

27 ft.lbs.

11/16 in

(27 Nm)

20 ft.lbs.

5/8 in

1. Plug
2. Plug
3. Plug
4. O-ring
5. O-ring

6. O-ring
7. Spring
8. Spring
9. Spring
10. Washer

11. Washer
12. Shift Spool
13. Orifice Poppet

Figure 3-18. Loop Flushing Spool

Advertising
This manual is related to the following products: