JLG 660SJ Service Manual User Manual

Page 266

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-20

– JLG Lift –

3121202

Table 6-2. Help Fault Codes, Displayed Faults, and Descriptions

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority

None

No flash code is indicated for the following help messages. They are
intended to hint at a possible problem if the vehicle is not behaving as
expected.

1

EVERYTHING OK

The “normal” help message in platform mode

GROUND MODE OK

The “normal” help message in ground mode

FSW OPEN

A drive or boom function has been selected but footswitch is open.

RUNNING AT CREEP –
CREEP SWITCH OPEN

All function speeds are limited to creep because the creep switch is open.

RUNNING AT CREEP – TILTED
AND ABOVE ELEVATION

All boom function speeds are limited to creep because the vehicle is tilted
and above elevation.

RUNNING AT CUTBACK –
ABOVE ELEVATION

Drive speed is limited to “ELEVATED MAX” because the vehicle is above
elevation.

TILT SENSOR OUT OF RANGE The tilt sensor has indicated a tilt angle greater than 19 degrees for more

than 4 seconds. Not reported during 2 second power-up.

LOAD SENSOR READING
UNDER WEIGHT

The load sensor is reading 20% or more under the calibrated zero point.
This fault may occur if the basket is resting on the ground. Not reported
during 2 second power-up.

1/1

Flash code 1/1 indicates a “sleep” mode.
NOT REQUIRED

2/1

Flash code 2/1 indicates problems with footswitch.

2

FSW FAULTY

The two footswitch inputs have read the same state for more than one sec-
ond.

KEYSWITCH FAULTY

Both platform and ground modes are selected simultaneously

2/2

Flash code 2/2 indicates problems with drive & steer selection. Except
where noted, these faults are not reported during 2 second power-up
sequence.

3

DRIVE LOCKED – JOYSTICK
MOVED BEFORE FOOT-
SWITCH

Drive was selected before and during footswitch closure. Can be reported
during power-up sequence.

FSW INTERLOCK TRIPPED

Footswitch was closed for seven seconds with no function selected. Can
be reported during power-up sequence.

STEER LOCKED – SELECTED
BEFORE FOOTSWITCH

Steer was selected before and during footswitch closure.

STEER SWITCHES FAULTY

Both steer switches are active together.

DRIVE / STEER WITH NO
QPROX

This fault only occurs with inductive joysticks. It occurs if the joystick is
moved out of the neutral position with no Qprox sensors active.

D/S JOY. QPROX BAD

These faults only occur with inductive joysticks. They indicate that the Q-
Prox sensor is reading above 3.18 volts.

D/S JOY. OUT OF RANGE LOW Resistive joysticks: These faults do not occur.

Inductive joysticks: The trigger points for these faults are dependent on the
centertap voltage reading. These faults will be triggered when the voltage
is less than the centertap voltage minus half the center tap voltage minus
0.3 volts. If the centertap is at the high end of the range, these faults will be
triggered below 1.05 volts. If the centertap is at the low end of the range,
these faults will be triggered below 0.79 volts.

Advertising