Tcp server mode for link mode – Atop Technology SE8502-M12 User Manual User Manual

Page 31

Advertising
background image

User manual Version 1.1
SE8502-M12 IP68 Serial Server

Copyright © 2010 Atop Technologies, Inc.

All rights reserved

27

Fig 38. Select COM Port from Serial Settings by Telnet

Fig 39. The COM1 Setting page

4.3.1.

TCP Server Mode for Link Mode


Operation: [Main]
Æ [4 Serial Settings] Æ [1 Link mode] Æ [1 TCP Server]

TCP Server mode is default setting for Link mode of serial settings of SE8502-M12, and it can be configured to wait
for the host computers to establish a connection with the serial device through SE8502-M12. SE8502-M12 needs to be
configure the listening port to waiting for host connection, Default Port number of SE8502-M12 is 4660 (4661) and it
is associated with the serial port COM1 (COM2). After the connection is established, data can flow in both directions.
SE8502-M12 can wait for connection requested from remote PC which installed “serial-to IP” tool or counter-pair
SE8502-M12 in tunneling mode. After the application program being connected to the TCP port 4660 (4661) on the
SE8502-M12, data of user application program are transmitted transparently to serial devices through SE8502-M12
and vice versa.

User enters 1 at COM1 (COM2) Settings page and enters 1 for the TCP Server mode. To enable the remote client
which install “serial-to IP” to connect to SE8502-M12, user has to enable the Virtual COM and Set up the
designated port number.

IP filtering menu is a simple ACL (Access Control List). It can be disabled by setting FILTER_IP to “0.0.0.0”. User
can configure one or group IPs for source IP in IP filtering. If IP filtering is enabled, only source IP assigned can
connect to SE8502-M12.