Serial settings – Atop Technology SE8502-M12 User Manual User Manual

Page 33

Advertising
background image

User manual Version 1.1
SE8502-M12 IP68 Serial Server

Copyright © 2010 Atop Technologies, Inc.

All rights reserved

29

Operation: [Main] Æ [4 Serial Settings] Æ [1 Link mode] Æ [3 UDP]

SE8502-M12 can be configured to work in UDP mode to establish connection using Unicast or Multicast protocol.
Data can be transmitted from one or multiple serial devices to/from one or multiple host PCs and vice versa. For
example, the original RS-422/ RS485 bus data is transferred over the extended connected distance by SE8502-M12s,
The destination IP is assigned by single IP or group IPs, The configuration is limited by the Local Listening Port,
default 4660 and 4661 on the COM1 and COM2 of SE8502-M12.

SE8502-M12 can support up to 8-group IPs for UDP connection, if users needed.

Fig 42. UDP mode in link mode

” Note: In this phase, UDP mode does not support Virtual COM mode.

4.3.4.

Serial Settings

Operation:
[Main]
Æ [4 Serial Settings] Æ [2 Baud rate]/ [3 Parity]/[4 Data bits]/ [5 Stop bits]/ [6 Flow control]

User can configure baud ratedata bits, paritystop bit and type of flow control.