Irtual, Ommunication – Atop Technology SE8502-M12 User Manual User Manual

Page 38

Advertising
background image

User manual Version 1.1
SE8502-M12 IP68 Serial Server

Copyright © 2010 Atop Technologies, Inc.

All rights reserved

34

A.3 Virtual COM Communication

Enable Virtual COM on SE8502-M12 by web interface

From web browser access to SE8502-M12 by typing its IP address, click on “Serial” link to access Serial page, on the
top half of the page click on “TCP Server” and enable Virtual COM by putting a check in front of the “Enable
checkbox, then type in the local port number in the “Local Port” field as indicated in the following screen.

Fig 49. Enable Virtual COM Mode by Web page


Enable Virtual COM on SE8502-M12 by Telnet

User may also enable Virtual COM through telnet by setting Serial as a TCP server, and enter the local port number for
Serial, then enable virtual COM as shown in the following procedure:


Login SE8502-M12 via Telnet

Fig 50. Login into SE8502-M12 by Telnet or Console

Select serial setting for TCP server/Client, and enabling Virtual COM mode