Chapter 4. Configuring the Display System

Street Dash Users Guide

23

Note: The gas pumps may shut off, if the gas delivery is

interrupted for a time.

2. Select the Fuel Tank Sender calibration display.

Hold Switch 1 down and press Switch 2. This gives a
display similar to the following:

Tank Qty 0G

Reading 255*

*Ohm Reading from sensor at Tank Qty value

(1) Use Switches 1 and 2 to change the Tank Qty value to

zero if it is not already zero. Switch 1 decreases the
value shown while Switch 2 increases it. Record the
Tank Qty and the Reading value in the table on page
25.

When you have set the Tank Qty to the required value,
press Switch 3 to set this value.

(2) Press Switch 1 to continue to the next calibration point.

(3) Fill the tank with a small, known amount of fuel, for

example, one gallon. If the Reading value does not
change, there is a problem with either the fuel sender
or the wiring.

(4) Wait for the Reading value to stabilize. This requires

several seconds. While you are waiting for the Reading
value to stabilize, use Switch 1 and Switch 2 to change
the Tank Qty value to the amount of fuel now in the
tank.

(5) When the Reading value has stabilized, press Switch 3

to set this value

(6) Repeat steps 6 through 9 above for each calibration

until the tank is full or you have performed at least two
or as many as ten calibration operations.

(7) Press Switch 2 (Finished) when you have completed

calibrating the fuel level readings.