Chapter 6. Troubleshooting

42

Street Dash Users Guide

No. Symptom Possible

Cause Remedy Notes

Pressure sensor
has failed

Replace sensor

Disconnect
sensor. If
reading
changes to
that in 7
above,
replace
sensor

8 Fixed

pressure

reading of -99 PSI

Faulty sensor
connections

Check continuity
of sensor leads
for short circuits

Check the
wiring
harness for
short circuit

9 Fixed

pressure

reading of 0 PSI
suspected low/slow
reading

Pressure sensor
has failed

Replace sensor


Faulty

sensor

connections

Check pressure
connections

Check
plumbing for
a blockage
(kinks in
flexible
hoses)

10

All sensors show
fixed high values

Switch 1 (Peaks)
faulty

Replace switch

Disconnect
switch. If
values return
to normal,
replace
switch.

Faulty switch wiring

Check switch
wiring

Check wiring
for short
between
connector
pins K and H
(ground)

11 Displays

pressure

values too low and
temperature values
too high

Low Battery voltage

Recharge battery

The system
does not give
accurate
readings
when voltage
is below 9.0V

Gate value set too
high

Change Gate
RPM in the
display
configuration
menu

Peak values
only updated
while the
engine RPM
is greater
than the
Gate value

12

Peak values not
updated

Internal memory
battery dead

Return unit to
Auto Meter for
new battery
service

Display
shows !!
Internal
Battery Low
!! warning on
power up

Advertising