Chapter 6. Troubleshooting

Street Dash Users Guide

41

No. Symptom Possible

Cause Remedy

Notes

5

Display gives a
fixed temperature
reading of 999

° F

Temperature
sensor has failed

Replace sensor

Disconnect
sensor. If
reading
changes to
0, replace
sensor.

Faulty

sensor

connections

Check the
continuity of
sensor leads: with
the sensor
disconnected and
the display
powered up, there
should be 6.25V
between the
sensor leads.

Otherwise
check
harness for
short circuit

A temperature
sensor has failed

Disconnect
sensor and short
its leads together.
If the reading
changes, replace
the sensor

6

Water or Oil
temperature
display gives a
fixed temperature
reading of 0

°F

when the water
temperature is
either above 55

°F

Faulty sensor
connections

Check continuity
of sensor leads
for open circuits.
See No. 5 above.

Check the
wiring
harness for
open circuits
(pin E to the
red OT
sensor wire,
pin P to the
red WT wire
and pin H to
both the
black OT and
WT sensor
wires)

Pressure sensor
has failed

Replace sensor

7 Fixed

pressure

reading of 999 PSI

Faulty sensor
connections

Check continuity
of sensor leads
for open circuits.
See 5 above.

Pin D to the
red OP wire,
pin R to the
red F wire
and pin H to
both the
black OP
and F sensor
wires

Advertising