Operating instructions – Autoquip FREIGHTLIFT FL4M User Manual

Page 82

Advertising
background image

82

DANGER

!

To avoid personal injury or death, do not operate this equipment with non-
factory, damaged, or missing parts or equipment supports. Contact a local
FREIGHTLIFT service representative if a deficiency is found.

WARNING

!

No riders! The FREIGHTLIFT is provided for the sole purpose of
transporting goods between floor elevations. At no time should it be used
to transport personnel.

WARNING

!


All gates and/or doors of the FREIGHTLIFT are electrically interlocked and
must be closed to permit operation the lift. Do not operate unit with doors
open or with the interlocks or other safety devices “defeated” (bypassed)!
Serious injury or death could result.

WARNING

!

Never operate the lift by “manualling” the electrical controls (using the
contactors located inside the control panel). All safety devices are by-
passed in this mode of operation and lift damage or severe personal injury
could occur.

NOTE: In order for the lift to operate:

 All gates/doors guarding the lift must be closed.
 Loads cannot hang over the edge or sides of the carriage.
 The load must be within the specified load capacity of the lift.
 All electrical safeties, sensors, and switches must be in their “closed” condition

UP

1. When an UP button on a push button station is pressed & released, the control

(secondary) circuit to the motor starter (motor contactor) is completed. The coil of
the motor starter magnetically closes the high (primary) voltage contacts completing
the power circuit to the motor.
NOTE: Per ASME B20.1, operator pushbutton stations must be located such
that they can not be activated while standing on the carriage

OPERATING INSTRUCTIONS

Advertising