Appendix, Upgrading firmware through cli – DATOptic ARC-1680 Series User Manual

Page 151

Advertising
background image

151

APPENDIX

Parameter:<path=<PATH_OF_FIRMWARE_FILE>>

Fn: Firmware Updating.

Ex: Update Firmware And File Path Is In [C:\FW\ARC1110FIRM.BIN.]

Command: sys updatefw path=c:\fw\arc1680firm.bin [Enter]

Upgrading Firmware Through CLI

This Command Line Interface (CLI) provides you to configure and

manage the Areca SAS RAID controller components in Windows,

Linux, FreeBSD and more environments. The CLI is useful in en-

vironments where a graphical user interface (GUI) is not avail-

able. Through the CLI, you perform firmware upgrade that you can

perform with the McRAID storage manager GUI. From firmware

version 1.43 and CLI version 1.72.250 beginning, the controller has

added the firmware update through the CLI on the controller.

To update the controller firmware, follow the procedure below:

A:\nflash

Raid Controller Flash Utility

V1.11 2007-11-8

Command Usage:

NFLASH FileName

NFLASH FileName /cn --> n=0,1,2,3 write binary to controller#0

FileName May Be ARC1680FIRM.BIN or ARC1680*

For ARC1680* Will Expand To ARC1680BOOT /FIRM/BIOS.BIN

A:\>nflash arc168~1.bin

Raid Controller Flash Utility

V1.11 2007-11-8

NODEL : ARC-1680

MEM FE620000 FE7FF000

File ARC168~1.BIN : >>*** => Flash 0K

Advertising