Bios configuration – DATOptic ARC-1680 Series User Manual

Page 83

Advertising
background image

BIOS CONFIGURATION

83

3.7.5.11 Controller Fan Detection

Included in the product box is a field replaceable passive heat-

sink to be used only if there is enough airflow to adequately cool

the passive heatsink.

The “Controller Fan Detection” function is available in the firm-

ware for preventing the buzzer warning. When using the passive

heatsink, disable the “Controller Fan Detection” function through

this McBIOS RAID manager setting.

The following screen shot shows how to change the McBIOS

RAID manager setting to disable the beeper function. (This

function is not available in the web browser setting.)

3.7.5.12 SAS Mux Setting (ARC-1680 Only)

The function is only for ARC-1680 Intel SAS controller limitation

of auto configuration of CH5-8 for internal or external. If there

is no linkage at the beginning power on stage, some SAS HDDs

PHY will automatically enter the sleep mode. In this condition,

our firmware will set no linkage on those channels. Since some

HDDs have this behavior, our controller firmware will configure

the active channel CH5-8 on the external port. We added this

function for customer to set, if the controller automatically

configuration function detect the wrong direction of CH5-

8 internal channels. Please set the "SAS MUX SETTING" to

I/O Port Addr : 28000000h, F2(Tab): Select Controller, F10: Reboot System

ArrowKey Or AZ:Move Cursor, Enter: Select, ESC: Escape, L:Line Draw, X: Redraw

Areca Technology Corporation RAID Controller

Main Menu

Quick Volume/Raid Setup

Raid Set Function

Volume Set Function

Physical Drives

Raid System Function

Hdd Power Management

Ethernet Configuration

View System Events

Clear Event Buffer

Hardware Monitor

System information

Raid System Function

Raid System Function

Mute The Alert Beeper

Alert Beeper Setting

Change Password

JBOD/RAID Function

Background Task Priority

SATA NCQ Support

HDD Read Ahead Cache

Volume Data Read Ahead

Hdd Queue Depth Setting

Empty HDD Slot LED

Controller Fan Detection

SAS Mux Setting

Auto Activate Raid Set

Disk Write Cache Mode

Capacity Truncation

Controller Fan Dectection

Controller Fan Detection

Enabled

Disabled

Advertising