Bios configuration, 1 view drive information, 2 create pass-through disk – DATOptic ARC-1680 Series User Manual

Page 73

Advertising
background image

BIOS CONFIGURATION

73

Choose this option from the main menu to select a physical disk

and perform the operations listed above. Move the cursor bar to

an item, then press Enter key to select the desired function.

3.7.4.1 View Drive Information

When you choose this option, the physical disks connected to

the SAS RAID controller are listed. Move the cursor to the de-

sired drive and press Enter key to view drive information.

I/O Port Addr : 28000000h, F2(Tab): Select Controller, F10: Reboot System

ArrowKey Or AZ:Move Cursor, Enter: Select, ESC: Escape, L:Line Draw, X: Redraw

Areca Technology Corporation RAID Controller

Main Menu

Quick Volume/Raid Setup

Raid Set Function

Volume Set Function

Physical Drives

Raid System Function

Hdd Power Management

Ethernet Configuration

View System Events

Clear Event Buffer

Hardware Monitor

System information

Physical Drive Information

Select The Drives

E#1Solt#2 : 500.1GB : HDS725050KLA360

E#1Solt#3 : 500.1GB : ST3500630NS

E#1Solt#4 : 400.1GB : Hitachi HDT725040VLA360

E#1Solt#5 : 400.1GB : Hitachi HDT725040VLA360

E#1Solt#6 : 400.1GB : Hitachi HDT725040VLA360

E#1Solt#7 : 500.1GB : HDS725050KL360

E#1Solt#8 : 500.1GB : ST3500630NS

E#1Solt#2 : 500.1GB : HDS725050KLA360

Ch01

Model Name : ST380013AS

Serial Number : 5JV944ZF

Firmware Rev. : 3.18

Disk Capacity : 80.0 GB

PIO Mode : Mode 4

Current UDMA : SATA150(6)

Supported UDMA : SATA150(6)

Device State : RaidSet Member

Timeout Count : 0

Media Errors : 0

SMART Read Error Rate : 200 (51)

SMART Spinup Time : 173 (21)

SMART Reallocation Count : 200 (140)

SMART Seek Error Rate : 200 (51)

SMART Spinup Retries : 100 (51)

SMART Calibration Retries : 100 (51)

3.7.4.2 Create Pass-Through Disk

A pass-through disk is not controlled by the SAS RAID controller

firmware and thus cannot be a part of a volume set. The disk is

available directly to the operating system as an individual disk.

It is typically used on a system where the operating system is

on a disk not controlled by the SAS RAID controller firmware.

The SCSI Channel/SCSI ID/SCSI LUN, Cache Mode, and Tag

Queuing must be specified to create a pass-through disk.

Advertising