Elkhart Brass Sidewinder 7161 EXM UHP User Manual

Page 18

Advertising
background image

EXM UHP– Operating Instructions

18

E. Keep-Out Zones
Keep-Out Zones are used when it is desired to restrict the motion of the monitor to a smaller more specific
range than that set during system calibration. Keep-Out Zones are different from travel limits in that they do
not restrict motion completely in any one direction. Keep-Out Zones can be set to allow the monitor to move
above a certain zone or beside the zone to either the left or right.

 Lower-Right Keep-Out Zone - The Right Keep-Out Zone will prevent the monitor from moving down

and to the right into a specified zone (reference figure 1 on the following page)

o Put the EXM system into Setup Mode (reference Part B of the Operating Instructions section)


o Move the monitor to the upper left corner of the keep out zone

o The Keep-Out Zone should be set within the previously set monitor calibration points. If a Keep-

Out Zone is set outside the intended operating area, operation of the monitor may be unpredictable.


o Press the PRESET and OPEN buttons at the same time

o When the EXM system is taken out of Setup Mode, the monitor will be prevented from moving

below and to the right of this point


 Lower-Left Keep-Out Zone - The Left Keep-Out Zone will prevent the monitor from moving down and

to the left into a specified zone (reference figure 1 below)

o Put the EXM system into Setup Mode (reference Part B of the Operating Instructions section)


o Move the monitor to the top right corner of the keep out zone

o The Keep-Out Zone should be set within the previously set monitor calibration points. If a Keep-

Out Zone is set outside the intended operating area, operation of the monitor may be unpredictable.


o Press the PRESET and CLOSE buttons at the same time


o When the EXM system is taken out of Setup Mode, the monitor will be prevented from moving

below and to the left of this point


Figure 1 – Keep-Out Zones

Advertising