Caution – Elkhart Brass Sidewinder 7161 EXM UHP User Manual
Page 5
EXM UHP– System Components
5
C. OEM Interface Module - 7070
The OEM Interface Module is used in conjunction with either the Elkhart
Brass or customer supplied joystick, or OEM installed switches. The OEM
Interface Module may be configured to handle switching power or ground.
The Interface Module provides the option of mounting a joystick or switches
in the apparatus cab to control all monitor functions, including oscillation.
The OEM Interface Module may be powered with 12 or 24 Volts.
D.
EXM Nozzles –
5000-14E UHP
The nozzle has a fixed flow rate with an electrically actuated stream
pattern adjustment
5000-14E UHP; 100 GPM.
Caution:
All
EXM monitor motors are 12VDC. If using a non-
EXM nozzle on the
EXM monitor, another 12VDC nozzle should
be used, or nozzle control may not function properly.
Figure 3: 00007070
OEM Interface Module
Figure 4: Sidewinder EXM UHP
Nozzle