Auxiliary Supply
Feature
Details
Auxiliary power supply
Isolated DC source only
Auxiliary supply input voltage
14 to 95 VDC (100 V models)
23 to 195 (200 V models)
Auxiliary supply input power
≤ 5 VA without external loading
≤ 8 VA with full external loading
3.2. Environmental Conditions
Feature
Operation Conditions
Range
Ambient
Temperature
Range
Non-operating conditions -50 °C to +100 °C (-58 °F to 212 °F)
Operating conditions
-40 °C to +70 °C (-40 °F to 160 °F)
Temperature
Shock
Non-operating conditions -40 °C to +70 °C (-40 °F to 160 °F) within 3
min
Altitude
Non-operating conditions Unlimited
Operating conditions
-400 m to 12,000 m (-1312 to 39370 feet)
Maximum
Humidity
Non-operating conditions Up to 95% non-condensing humidity at 35 °C
(95 °F)
Operating conditions
Up to 95% non-condensing humidity at 25 °C
(77 °F), up to 90% non-condensing humidity
at 42 °C (108 °F)
Vibration
Operating conditions
20 Hz to 2000 Hz, 14.6g
Mechanical
Shock
Non-operating conditions ±40g; Half sine, 11 msec
Operating conditions
±20g; Half sine, 11 msec