Bell Installation Guide

Bell Technical Specifications

MAN-BELIG (Ver. 1.302)

|

www.elmomc.com

47

Table of Contents

4.3. Environmental Conditions

Feature

Details

Operating ambient temperature

according to IEC60068-2-2

0 °C to 40 °C (32 °F to 104 °F)

Storage temperature

-20 °C to +85 °C ( -4 °F to +185 °F)

Maximum non-condensing humidity

according to IEC60068-2-78

95%

Maximum Operating Altitude

2,000 m (6562 feet)

Mechanical Shock

according to IEC60068-2-27

15g / 11ms Half Sine

Vibration

according to IEC60068-2-6

5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G

4.3.1.

Auxiliary Supply

Feature

Details

Auxiliary power supply

Isolated DC source only

Auxiliary supply input voltage

12 VDC ~ 95 VDC

Auxiliary supply input power

< 2.5 VA (this includes the 5 V/200 mA load for the
main encoder only)