4.5.3.
Auxiliary Feedback Port (input mode YA[4]= 2, 0)
Feature
Details
Encoder input,
pulse and direction input
•
A, B, Index
•
Single ended
Output current capability
V
In
Low: 0 V < V
IL
< 0.8 V
V
In
High: 2 V < V
IH
< 5 V
Maximum absolute voltage: 0 < V
In
< 5.5 V
Input current: ±1 μA
Available as options
•
Single-ended encoder inputs
•
Pulse and direction inputs
Edge separation between A & B
Programmable number of clocks to allow adequate
noise filtering at remote receiver of encoder signals
Index (marker):
Length of pulse is one quadrature (one quarter of an
encoder cycle) and synchronized to A & B
Figure 24: Auxiliary Feedback - Encoder Phase Diagram