Fault protection, System architecture – ElmoMC ExtrIQ Digital Servo Drives-Panther User Manual

Page 16

Advertising
background image

Panther Installation Guide

Product Description

MAN-PANIG (Ver. 1.302)

www.elmomc.com

16

2.3.7.

Fault Protection

The Panther includes built-in protection against possible fault conditions, including:

Software error handling

Status reporting for a large number of possible fault conditions

Protection against conditions such as excessive temperature, under/over voltage, loss of

commutation signal, short circuits between the motor power outputs and between each
output and power input/return

Recovery from loss of commutation signals and from communication errors

2.4. System Architecture

Motor

PWM

Controller

Communication

RS 232 and CANopen

Isolated Power Stage

Protection

I/Os

Resolver

Tachometer

Analog

Encoder

or

Main

DC Power

Supply

Potentiometer

or

or

or

Auxilliary

Encoder

24V Logic

Supply

(Optional)

Isolation

Boundary

Isolation

Boundary

Current

Feedback

Incremental

Encoder

Absolute

or

Figure 1: Panther System Block Diagram