I/os, Digital input interfaces – ElmoMC ExtrIQ Digital Servo Drives-Panther User Manual

Page 84

Advertising
background image

Panther Installation Guide

Technical Specifications

MAN-PANIG (Ver. 1.302)

www.elmomc.com

84

4.10. I/Os

The Panther has:

6 Digital Inputs

4 Digital Outputs

1 Analog Input

4.10.1. Digital Input Interfaces

The digital inputs are 5 V level compatible by default, but can be configured to PLC level, on the
integration board.

Feature

Details

Type of input

Optically isolated

Each input has its own return

Input current for all inputs

Iin = 4.7 mA @ Vin = 5 V

High-level input voltage

3.0 V < Vin < 10 V, 5 V typical

Low-level input voltage

0 V < Vin < 1 V

Minimum pulse width

> 4 x TS, where TS is sampling time

Execution time (all inputs):
the time from application of
voltage on input until execution is
complete

If input is set to one of the built-in functions — Home,
Inhibit, Hard Stop, Soft Stop, Hard and Soft Stop,
Forward Limit, Reverse Limit or Begin — execution is
immediate upon detection: 0 < T < 4 x TS
If input is set to General input, execution depends on
program. Typical execution time: ≅ 0.5 msec.

High-speed inputs – 5 & 6
minimum pulse width, in high-
speed mode

Capture Time (T) < 5 µsec

Notes:

Home mode is high-speed mode and can be used

for fast capture and precise homing.

High speed input has a digital filter set to the same

value as the digital filter (EF) of the main encoder.

The highest speed is achieved when turning on

optocouplers.

Figure 41: Digital Input Schematic

Advertising