Feedbacks, Feedback supply voltage, Main feedback options – ElmoMC ExtrIQ Digital Servo Drives-Panther User Manual
Page 78: Incremental encoder input
Panther Installation Guide
Technical Specifications
MAN-PANIG (Ver. 1.302)
78
4.9. Feedbacks
The Panther can receive and process feedback input from diverse types of devices.
4.9.1.
Feedback Supply Voltage
The Panther has two feedback ports (Main and Auxiliary). It supplies voltage to the Main
feedback device, and to the Auxiliary feedback device if needed.
Feature
Details
Main encoder supply voltage
5 V ±5% @ 200 mA maximum
Auxiliary encoder supply voltage
5 V ±5% @ 200 mA maximum
4.9.2.
Main Feedback Options
4.9.2.1.
Incremental Encoder Input
Feature
Details
Encoder format
•
A, B and Index
•
Differential
•
Quadrature
Interface
RS-422
Input resistance
Differential: 120 Ω
Maximum incremental encoder frequency
Maximum absolute: 5 MHz pulses
Minimum quadrature input period (P
IN
)
112 nsec
Minimum quadrature input high/low period (P
HL
) 56 nsec
Minimum quadrature phase period (P
PH
)
28 nsec
Maximum encoder input voltage range
Common mode: ±7 V
Differential mode: ±7 V
Figure 38: Main Feedback - Encoder Phase Diagram