B single-phase direct-to-mains connection topology, Figure 7 – ElmoMC ExtrIQ Digital Servo Drives-Panther User Manual

Page 32

Advertising
background image

Panther Installation Guide

Installation

MAN-PANIG (Ver. 1.302)

www.elmomc.com

32

3.7.2.1.b

Single-Phase Direct-to-Mains Connection Topology

Figure 7: Non-Isolated Single-Phase Connection Topology

The Power Supply is connected directly to the Mains AC line.

Caution:
Do not connect VN- to PE. In a direct-to-mains connection the VN- must not be
connected to the PE, as this will cause irreparable damage to the system.
Take care and note that in a direct-to-mains connection the Neutral point is not
the most negative voltage level. It is the mid-point level of the rectified DC bus.

Advertising