Configure ethernet interface, Commissioning – Lenze HMI for visualisation / with control technology User Manual

Page 39

Advertising
background image

Commissioning

Establish Ethernet connection

Configure Ethernet interface

7

l

39

LDCDS−EL100 EN 9.0

7.3.1

Configure Ethernet interface

Prerequisite:

ƒ

The EL 1xx is physically connected to the fieldbus via Ethernet interface.
– Network (with router): via Ethernet cable
– Peer−to−peer (without router): via crossed Ethernet cable (cross−over)

ƒ

The EL 1xx is switched−on.

How to proceed:

1. Click Start

® Settings ® Network and Dial−up Connections on your EL 1xx.

2. Click the Dm9CE1 connection and configure the following dialogue via network

interface.

EL100−021

3. Click OK.

)

Note!

Modifications are not stored automatically in the Registry. This means that
they will be lost after a restart.
If you wish to make permanent modifications, proceed as follows:

ƒ

Click Start

® Settings ® Control Panel ® Registry on your EL 1xx.

ƒ

Click Save.

4. If an IP address assignment via DHCP Server was specified when configuring the

interface (only available for networks with router), restart the EL 1xx.

5. Double−click the network symbol down right in the status bar and check the

settings.