Operation

Communicating via the CAN gateway function
Establishing communication using the system bus configurator

8

l

80

LDCDS−EL100 EN 9.0

)

Note!

Alternatively, the Ethernet settings from the EL100 communication module
can also be read in online. Please ensure that the communication module is
not positioned behind routers or firewalls so that the Ethernet settings can be
read in.
Reading in Ethernet settings:

ƒ

Left−click the value of the MAC address.

ƒ

In the "Edit MAC address", click Search.
After a while, the "Identified communication modules" dialog is displayed.

ƒ

Select the module to be used for communication.

ƒ

You can either accept only the MAC address or all Ethernet settings by
clicking the corresponding button.

Activating and diagnosing communication

)

Note!

Communication via the Global Drive Control (GDC) or the L−force Engineer only
works if the EL1xx has been defined as the standard device.

5. Right−click the communication module and select Activate from the context menu

to activate communication.
An activated device is indicated by a red check mark in the "active/default" column.

6. Define the EL1xx communication module as the standard device by another

right−click on the communication module in the system bus configurator and
selecting Default from the context menu.
The standard device is indicated by a black check mark in the "active/default" column.

EL100−038

7. Select the new module in the system bus configurator.

8. For communication diagnostics, open the "Common" tab and click the

Communication diagnostics button.
A message is displayed. Please observe the note contained therein saying that wrong
settings may lead to a bus switch−off and that Lenze will not accept any responsibility
or liability for damage which might possibly occur.