Maintenance – Lenze HMI for visualisation / with control technology User Manual

Page 92

Advertising
background image

Maintenance

Battery replacement

9

l

92

LDCDS−EL100 EN 9.0

How to proceed:

1. Remove all connected cables and the SD card.

2. Remove the device and put it face−down on a table.

Make sure that the display is not damaged by parts on the table.

3. Remove PC housing:

0

1

1

1

1

0

0

2

3

0

EL100−035

– Loosen 4 screws

0. Do not loosen screw 2!

– Loosen 4 screws

1.

– Carefully remove the housing

3. Please observe that the housing is connected to

the baseboard by a cable (PE connection

2).

4. Exchange battery:

4

EL100−036

– Remove the dead battery

4 from the unit.

– Insert new battery

4with the positive pole up.

5. Mount PC housing:

– Carefully put the housing

3onto the baseboard. The PE cable must not be bent in

the process.

– Insert and tighten 4 screws

0and 4 screws 1.

According to European legislation you are obliged to dispose of batteries separately, using
the take−back systems specified.