21

MK-Scarifier aSSeMBLY

cUTTiNg DrUM aSSeMBLY

cutting Drum removal

(A)

Rotate the Scarifier to rest on

the Handle/Stand. Never rest

on back handle bar.

(B)

Locate the Shaft Cover, Re-

taining Bolts.

(C)

Remove the Shaft Cover,

Rear Retaining Bolt and

loosen the Front Retaining

Bolt using 9/16 wrenches

and/or sockets.

(D)

Pivot the Shaft Cover to

expose the end of the Cutting

Drum Shaft.

(E)

Remove the Shaft, Retain-

ing Nut Cover from the Belt

Guard to expose the Shaft,

Retaining Nuts.

(F)

Rotate counterclockwise to

using a 15/16-inch socket,

loosen the Outer Shaft, Re-

taining Nut.

(G)

Place an index finger on the

end of the Cutting Drum,

Shaft

(H)

Remove the Outer Shaft, Re-

taining Nut using your middle

finger as shown

(I)

Repeat Step H for the Inner

Shaft, Retaining Nut

Because the Cutting Drum assembly is a complex process, the assembly procedure will be broken

into several parts.