Appendix a, Guardnvr installation checklist, Guardnvr installation manual – Quadrox QGuard Installation Manual User Manual

Page 75

Advertising
background image

GuardNVR Installation Manual

75


Version 4.4 Series

Appendix A

GuardNVR installation checklist

Please check that you performed all steps listed below:

Hardware connections:

1.

Connecting the power outlets to the GuardNVR, cameras and the network
switches.

2.

Establishing a network connection between all of the devices by connecting each
of them to a network switch using UTP network cables

Configuring the GuardNVR’s IP-address

Configure the cameras by:

1.

Giving all cameras a static IP address using the Camera Setup CD-ROM.

2.

Giving all cameras a user name and password.

3.

Adding all the cameras to the GuardNVR Web Application using the correct
static IP address, user name and password assigned in the steps above.

4.

Setting all the camera parameters, such as the camera quality (resolution),
recorded frames per second and compression type.

5.

Setting the activity detection level & masking correctly.

Checking for the presence of recordings for all connected cameras storage folder you
selected during installation.

Verifying the combined CPU consumption of the GuardNVR is not higher than 55%
when all connected cameras are simultaneously recording.

Changing the default passwords into strong passwords. The passwords are changed in
the User management of the GuardNVR application.

Checking access to the GuardNVR from a remote unit of the network.

Saving the GuardNVR settings using the Save Configuration feature in the System
info
screen.

Configuring a router (not needed when the GaurdNVR is not accessed from an
external location)

Opening TCP ports 1518 and 80.

Opening the UDP port range 4096 ~ 4223

Opening the TCP port 3389

Opening the TCP 5666 if your server is monitored by the Quadrox Q-Monitor
Service.

Forwarding all of the above ports to the internal IP address of the GuardNVR

Above are the default ports. Note that these ports change when the default ports
are changed in the GuardNVR settings

Checking the Internet connection.