SATEC PM296 User Manual

Page 75

Advertising
background image

Appendix: Technical Specifications

67

Parameter

Full scale

Accuracy, %

Range

Display resolution (%Rdg)

@

input

Rdg

FS

Conditions

@ range

current

Starting current 0.5% FS

Auxiliary current

AUXILIARY CT PRIMARY
CURRENT

0.1 0.1

1% to 200% FS

0 to 9999 A/mA

0.01 A/mA @ 0.01A/mA to 99.99 A/mA
≤0.1% @ 100.0 A/mA to 9999 A/mA
Starting current 0.5% FS

DC Voltage

20, 100, 300 VDC (upon
order). Can be scaled up to
9999.

0.3

1% to 100% FS

0 to 9999 VDC

0.01VDC @ 0.01 to 99.99 VDC
≤0.1% @ 100.0 to 9999 VDC
Starting voltage 2% FS

Ampere demand

same as for current

kW demand (block & sliding) according to active power accuracy
kvar demand according to reactive power accuracy
KVA demand (block & sliding ) according to apparent power accuracy
Total Harmonic
Distortion, THD
U (I), % U1 (I1)

999.9 1.5

0.2

≥ 1% FS, U (I) ≥
10% FSU (FSI)

0 to 999.9

0.1

Total Demand
Distortion, TDD, %

100

1.5

≥ 1% FS,
I

≥ 10% FSI

0 to 100

0.1

Active energy
Import & Export

Class 0.2S (IEC 687-1992-6) 0 to 999,999.999 MWh PM296:

1 kWh @ 1 to 999,999,999 kWh
RPM096:
1 kWh @ 1 to 999,999 kWh
10 kWh @ 1000 to 9,999.99 MWh
100 kWh @ 10,000 to 99,999.9 MWh
1MWh @ 100,000 to 999,999 MWh

Reactive energy
Import & Export

Class 0.2, under conditions as

per IEC 687-1992-6

0 to 999,999.999 Mvarh PM296:

1 kvarh @ 1 to 999,999,999 kvarh
RPM096:
1 kvarh @ 1 to 999,999 kvarh
10 kvarh @ 1000 to 9,999.99 Mvarh
100 kvarh @ 10,000 to 99,999.9 Mvarh
1Mvarh @ 100,000 to 999,999 Mvarh

Apparent energy

Class 0.2, under conditions as

per IEC 687-1992-6

0 to 999,999.999 MVAh PM296:

Advertising