Installation, Venting introduction – Regency Bellavista B36XT Medium Gas Fireplace User Manual

Page 17

Advertising
background image

Regency Bellavista™ B36XT Gas Fireplace

17

INSTALLATION

7) From the outside top of the fi rebox - remove the intake cover plate

by removing the 4 - 1/4" x 1/2 " screws. See Diagram 7.

6) From the outside top of the fi rebox - remove top insulation cover

plate and insulation fi lling - by removing 4 screws. See Diagram 6.

Discard cover plate and insulation fi lling.

5) From the outside rear of the fi rebox, remove the intake collar

assembly. Remove the 4 - 1/4" x 1/2" screws. See Diagram 5.

Diagram 5

Exhaust

Assembly

Intake Collar

Assembly

Diagram7

Diagram 6

Before proceeding to Step 8, inspect condition of all gaskets.
DO NOT install parts with damaged gaskets. Replace if necessary

with spare gaskets supplied.

8) From the inside of the fi rebox, place the exhaust assembly into

position as shown in Diagram 8 and secure with 8 - 1/4" x 1/2" screws
(Diagram 9). Ensure all screws are tight, but do not over tighten.

All 8 screws must be used.

Diagram 8

Diagram 9

10) From the outside rear of the fi rebox, install the intake cover plate

with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not
over tighten. All 4 screws must be used.

11) Set vent restrictor accordingly - see next page.

12) From inside the fi rebox, re-install the baffl e plate and heat
defl ector - reverse steps 2 & 3.

9) From the outside top of the fi rebox, install the intake collar assembly.

Secure with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but
do not over tighten. All 4 screws must be used.

Diagram 11

Intake Collar

Assembly

Exhaust

Assembly

Diagram 10

VENTING

INTRODUCTION

The B36XT uses the "balanced fl ue" technology Co-Axial system.
The inner liner vents products of combustion to the outside while the
outer liner draws outside combustion air into the combustion chamber
thereby eliminating the need to use heated room air for combustion
and losing warm room air up the chimney.

Note: These

fl ue pipes must not be connected to any other

appliance.

The gas appliance and vent system must be vented directly to the

outside of the building, and never be attached to a chimney serving

a separate solid fuel or gas burning appliance. Each direct vent gas

appliance must use it's own separate vent system. Common vent

systems are prohibited.

Advertising