Installation, Venting arrangements with co-linear flex system – Regency Bellavista B36XT Medium Gas Fireplace User Manual

Page 33

Advertising
background image

Regency Bellavista™ B36XT Gas Fireplace

33

INSTALLATION

VENTING ARRANGEMENTS

WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE

CONNECTED TO A CHIMNEY FLUE

SERVING A SEPARATE SOLID FUEL

BURNING APPLIANCE.

This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. See the Venting
Arrangements on next page for minimum and
maximum heights.

Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical

Termination

Cap

948-305

3" Flex - 35 ft.

946-563

Co-Axial to Co-Linear Adapter Kit

which contains the following:

Co-linear Flex Adapter

Outer

Pipe

Inner

Pipe

Adapter

770-994 Rigid

Pipe

Adaptor

946-606 Vent Reducer

Alternate Approved Caps

46dva-VC Vertical Termination Cap
46dva-VCH High Wind Cap
46dva-GK 3" Co-linear Adapter with fl ashing

Flex Liner

Exhaust

Flue

A maximum

of two certified

joiner kits

may be used

per length.

#948-305 (35 ft)

Air Intake

Co-linear DV

Vertical Termination

Cap # 946-529

Co-Linear

Flex

Adapter

with Kit#

946-563

Outer

Pipe

with Kit#

946-563

Inner Pipe

Adapter

with Kit#

946-563

Rigid Pipe Adapter

# 770-994

90 Degree

Elbow

Pipe Length

Reducer #946-606

(4 x 6-5/8 venting)

NOTE:
See detailed venting arrangements,
vertical terminations, co-linear fl ex system

into masonry fi replaces in this manual.

Advertising