Maintenance, Log replacement, Thermopile / thermocouple – Regency Bellavista B36XT Medium Gas Fireplace User Manual

Page 61: Glass gasket, Door glass, Maintenance instructions, Bulb replacement

Advertising
background image

Regency Bellavista™ B36XT Gas Fireplace

61

MAINTENANCE

liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fi ttings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.

4) Inspect joints, to verify that no pipe sections or

fi ttings have been disturbed, and consequently
loosened. Also check mechanical supports
such as Wall Straps, or plumbers' tape for
rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the logs.
(The pilot light generates enough heat to burn
someone.) If for any reason a log should need
replacement, you must use the proper replacement
log. The position of these logs must be as shown
in the diagrams under Log Installation.

Note: Improper positioning of logs may create

carbon build-up and will severely alter
the unit's performance which is not
covered under warranty.

THERMOPILE /

THERMOCOUPLE

1) Open the Bottom Louvers or Grills. Remove

the Top Louver or Grill.

2) Remove the Trim Kit, Glass Door, Log Set,

Grate and Burner Assembly (see the "Log
Installation" & "Glass Door Removal" sections).

3) Disconnect thermocouple by loosening nut

from the valve with a 9mm wrench. Disconnect
thermopile by loosening 2 screws marked TP
on the valve.

4) Remove 2 screws from the pilot assembly

and pull up far enough to be able to loosen
the thermocouple or thermopile with a 7/16"
wrench. NOTE: the pilot line is very fragile,
use caution when pulling it up.

5) Drop the thermocouple or thermopile down

through the extrusion and pull it out of the unit.

6) Reinstall the new ones in reverse order.

GLASS GASKET


If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).

DOOR GLASS

Your Regency

®

fi replace is supplied with high

temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.

CAUTION & WARNINGS:

* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fi replace without the
glass front or with a cracked or broken
glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualifi ed service per
son.

GLASS REPLACEMENT

In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass
(Part #940-357/P) is shipped already installed
into the door frame. Reinstall as per Glass
Door Installation in the "Glass Door Removal"
section.

MAINTENANCE

INSTRUCTIONS

1) Always turn off the gas valve before cleaning.

For relighting, refer to lighting instructions. Keep
the burner and control compartment clean by
brushing and vacuuming at least once a year.
When cleaning the logs, use a soft clean
paint brush as the logs are fragile and easily
damaged.

2) Clean appliance and door with a damp cloth

(never when unit is hot). Never use an abrasive
cleaner. The glass should be cleaned with a
gas fi replace glass cleaner. The glass should
be cleaned when it starts looking cloudy.

3) The heater is fi nished in a heat resistant

paint and should only be refi nished with heat
resistant paint. Regency

®

uses StoveBright

Paint - Metallic Black #6309.

4) Make a periodic check of burner for proper

position and condition. Visually check the
fl ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating.
If there is a problem, call a qualifi ed service
person.

5) The appliance and venting system must be

inspected before use, and at least annually,
by a qualifi ed fi eld service person, to ensure
that the fl ow of combustion and ventilation air
is not obstructed.

Note: Never operate the appliance without the

glass properly secured in place.

6) Do not use this appliance if any part has been

under water. Immediately call a qualifi ed service
technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.

7) In the event this appliance has been serviced

check that the vent-air system has been
properly resealed & reinstalled in accordance
with the manufacturer's instructions.

8) Verify operation after servicing.

General Vent Maintenance

Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:

1) Check the Venting System for corrosion in areas

that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.

2) Remove the Cap, and shine a fl ashlight down

the Vent. Remove any bird nests, or other
foreign material.

3) Check for evidences of excessive condensation,

such as water droplets forming in the inner

1) Follow steps 1- 4 on page 53.

2) Remove 2 screws to remove light diffuser
plus gasket.

3) Replace the bulb - do not touch bulb with
bare hands, use gloves or bulb packaging
to protect bulb.

4) Reverse steps.

BULB REPLACEMENT

Advertising