Installation – Regency Bellavista B36XT Medium Gas Fireplace User Manual

Page 18

Advertising
background image

18

Regency Bellavista™ B36XT Gas Fireplace

INSTALLATION

VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION

NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL PANEL INSTALLATION.

Note: If installing brick/optional panels, see brick/optional panel

instructions before proceeding to next step.

Diagram 2 Vent restrictor installed on top exhaust assembly

6) From inside the fi rebox, install the baffl e plate with 4 - 1/4" x 1/2 "

screws. Ensure all screws are tight, but do not over tighten.

Baffl e Plate

Diagram 3

7) From inside the fi rebox, install the top heat defl ector with 2 -
1/4" x 1/2" screws. Ensure all screws are tight, but do not over

tighten.

Heat Defl ector

Diagram 4

1) Determine the venting confi guration.

2) Remove top heat defl ector and baffl e plate (reverse of steps 5 & 6).

3) Go to venting arrangements section (in the manual) to determine if
a vent restrictor setting is required.

Note: The vent restrictor does not apply to rear vent applications.

4) Align the vent restrictor plate to the required vent restrictor position
as per the diagrams shown.

5) Once the vent restrictor plate is in the required position, secure with

2 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over

tighten. (See diagram 2).

Advertising