Regency Bellavista™ B36XT Gas Fireplace

INSTALLATION

WIRING DIAGRAM

AERATION ADJUSTMENT

LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT

TO MAKE OUTLETS INDEPENDENT OF EACH OTHER

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.

Minimum Air Shutter Opening:

NG 1/4"

LP 3/8"

CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.

Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.

CAUTION: Carbon will be produced if air shutter

is tightly closed.

Note: Any damage due to carboning

resulting from improperly setting
the aeration controls is NOT covered
under warranty.

This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat
will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation, Profl ame GTMF, and light options.

(Do not cut the ground terminal off under any circumstances.)

NOTE: Even if the fan, GTMF system or light options are not purchased with the unit, it is still a good idea to bring power to the receptacle box (pro-
vided with the unit) in case the optional fan or light is installed at a later date.

Air shutter rod - located to the left

of the valve assembly.

Lockwasher

Fan

ground wire

Nut

#8 Ground Lug

(mobile home

approved)

Star washer

Ground

Green

Neutral

Live

Black

Red

Red

Minimum Convection

Air Temp. Switch

Ground

ON

OFF

Rotary Speed

Control

120V AC
60 Hz

Fan

Optional Fan

Light

Switch

Receptacle

in Unit

To Fan (see above)

Optional Accent Light

Ground

L1

N

Black

Red

Ground

Break Tab

Copper terminals

Black

Do Not Break Tab

on Neutral (silver terminals)

Fan

Switch

Green

ELECTRICAL WORK MUST BE
PERFORMED BY A QUALIFIED
ELECTRICIAN