Installation, Vertical height (feet) horizontal (feet), Venting arrangements for horizontal terminations – Regency Bellavista B36XT Medium Gas Fireplace User Manual

Page 28

Advertising
background image

28

Regency Bellavista™ B36XT Gas Fireplace

INSTALLATION

16

2

2

0

0

12

12

6

6

18

18

4

49"
(1245mm)
Minimum
Height
Requirement

4

14

8

8

10

10

14

16

18

18

20

V

ertical

Height

(Feet)

Horizontal (Feet)

Restrictor 2-1/4” Open

Set 1

No Vent Restrictor

VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS

RIGID PIPE 4" X 6-5/8"

(MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR)

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90

o

two 45

o

elbows equal one 90

o

elbow).

• Maintain clearances to combustibles as listed in "Clearances"

section

• Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever

passing through a wall.

A wall thimble is mandatory for all horizontal terminations
due to high temperatures.

ALL RIGID PIPE SYSTEMS

4" INNER DIAMETER

6-5/8" OUTER DIAMETER