Rockwell Automation Publication 20B-IN019E-EN-P - July 2013

47

PowerFlex 700 Adjustable Frequency AC Drive – Frames 0…6

Fram

e

Vo

lt

ag

e

Code

Current

Ra

ti

ng

Factory Default Jumper Settings

Power Source Type

MOV/Input
Filter Caps

(1) (2)

DC Bus Common
Mode Caps

5

IP20, NEMA/UL Type 1 and Open Drives (continued)

C
F

W

140
052
060

Two green/yellow
wires connected to
the Power
Terminal Block rail

Green/yellow wire to
CM Cap Board is
connected to ground

Solid Ground

1. CM Cap jumper wire must be connected to

ground with a metal screw. Verify, and if
necessary, remove the nylon screw/spacer and
insert a metal M5 x 8 screw. Torque to 3.2 N•m
(28 lb•in).

2. MOV/Input Filter Cap jumper wires must be

connected to ground with a metal screw.
Verify, and if necessary, remove the nylon
screw/spacer and insert a metal M5 x 12
screw.

Non-Solid Ground

1. CM Cap jumper wire must be insulated from

ground with a nylon screw/spacer. Verify, and
if necessary, remove the metal screw and
insert a M5 x 15 nylon screw/spacer.

2. MOV/Input Filter Cap jumper wires must be

insulated from ground with a nylon screw/
spacer. Verify, and if necessary, remove the
metal screw and insert a
M5 x 20 nylon screw/spacer.

E
F
T

W

077
082
099
098

Two green/yellow
wires connected to
chassis ground

Green/yellow wire to
CM Cap Board is
connected to ground

Solid Ground

1. CM Cap jumper wire must be connected to

ground with a metal screw. Verify, and if
necessary, remove the nylon screw/spacer and
insert a metal M5 x 8 screw. Torque to 3.2 N•m
(28 lb•in).

2. MOV jumper wire must be connected to

ground with metal screws. Verify, and if
necessary, remove the nylon screw/spacers
and insert a metal M5 x 12 screws.

3. Input Filter Cap jumper wire must be

connected to ground with a metal screw.
Verify, and if necessary, remove the nylon
screw/spacer and insert metal M5 x 8 screw.

Non-Solid Ground

1. CM Cap jumper wire must be insulated from

ground with a nylon screw/spacer. Verify, and
if necessary, remove the metal screw and
insert a M5 x 15 nylon screw/spacer.

2. MOV jumper wire must be insulated from

ground with a nylon screw/spacer. Verify, and
if necessary, remove the metal screws and
insert a M5 x 20 nylon screw/spacer.

3. Input Filter Cap jumper wire must be insulated

from ground with a nylon screw/spacer. Verify,
and if necessary, remove the metal screws and
insert a M5 x 15 nylon screw/spacer.

Frame 5 continued on next page

(1) AC input drives only. MOV’s and input filter caps do not exist on DC input drives.

(2) When removing MOV’s, the input filter capacitor must also be removed.

WIRE RANGE: 14-1/0 AWG (2.5-35 MM2)
TORQUE: 32 IN-LB (3.6 N-M)
STRIP LENGTH: 0.67 IN (17 MM)
USE 75 C CU WIRE ONLY

POWER TERMINAL RATINGS

WIRE RANGE: 6-1/0 AWG (16-35 MM2)
TORQUE: 44 IN-LB (5 N-M)
STRIP LENGTH: 0.83 IN (21 MM)

GROUND TERMINAL RATINGS (PE)

300 VDC EXT PWR SPLY TERM (PS+, PS-)

WIRE RANGE: 22-10 AWG (0.5-4 MM2)
TORQUE: 5.3 IN-LB (0.6 N-M)
STRIP LENGTH: 0.35 IN (9 MM)

17

21

INPUT AC

OUTPUT

Optional

Communications

Module

9

CM Cap

MOV

MOV / Input Filter Cap

WIRE RANGE: 14-1/0 AWG (2.5-35 MM2)
TORQUE: 32 IN-LB (3.6 N-M)
STRIP LENGTH: 0.67 IN (17 MM)
USE 75 C CU WIRE ONLY

POWER TERMINAL RATINGS

WIRE RANGE: 6-1/0 AWG (16-35 MM2)
TORQUE: 44 IN-LB (5 N-M)
STRIP LENGTH: 0.83 IN (21 MM)

GROUND TERMINAL RATINGS (PE)

300 VDC EXT PWR SPLY TERM (PS+, PS-)

WIRE RANGE: 22-10 AWG (0.5-4 MM2)
TORQUE: 5.3 IN-LB (0.6 N-M)
STRIP LENGTH: 0.35 IN (9 MM)

17

21

INPUT AC

OUTPUT

Optional

Communications

Module

9

PE

CM Cap

MOV

MOV

Input Filter
Cap