Chapter 4

Installation

4-7

Figure 4.5

Typical 115 VAC Digital Input Connections Using Internal Power Source

4

6

47

48

49

50

51

TB3

115V AC Common

Digital Common

Digital In 1

Digital In 2

Digital In 3

Digital In 4

Stop

Jog 2

Start

Clear Faults

Figure 4.6

Typical 115 VAC Digital Input Connections Using External Power Source

47

48

49

50

51

TB3

115 VAC Common

Digital Common

Digital In 1

Digital In 2

Digital In 3

Digital In 4

Stop

Jog 2

Start

Clear Faults

115 VAC High