Run Up/Coast Down Extension Module Chapter 2
The resulting time waveform is recorded as a Microsoft Windows .wav file
and the Acquisition Completed dialog appears on the screen.
6.
Press F4 (OK) to continue.
The RUCD - Display Select screen appears.
The Dynamix 2500 data collector provides five different formats for you to
use to view the newly recorded time waveform.
7.
Select the format and press F3 (Display).
TIP
If an error occurs during data collection, a message
appears in this dialog box.
Format
Description
Bode
Displays the magnitude and phase over a varying rpm.
Displaying Measurements by Using a Bode Plot on page 22
Nyquist
Displays the selected orders as complex data.
Displaying Measurements Using a Nyquist Plot on page 25
.